How Bushfire Attack Levels (BAL) Dictate Roofing Materials
If your property backs onto bushland, sits on a ridge, or borders a grassy paddock anywhere in South-East Queensland, there is a good chance it falls inside a designated bushfire-prone area. When that happens, your roof is no longer just a design choice. The roof is the part of your home most exposed to burning embers, so building rules treat it as a critical line of defence. The rating that controls what you can install is called the Bushfire Attack Level (BAL).
This guide explains what BAL ratings mean, how they are determined, which roofing materials and components suit each level, and what to consider if you are building, renovating or replacing a roof in Brisbane, the Gold Coast, the Sunshine Coast, Moreton Bay, Ipswich, Logan, Redlands or the Scenic Rim.
What Is a Bushfire Attack Level?
A BAL is a measure of a building site's potential exposure to ember attack, radiant heat and direct flame contact during a bushfire. It is set out in AS 3959:2018, Construction of buildings in bushfire-prone areas, which is referenced by the National Construction Code (NCC). The rating is expressed in kilowatts per square metre (kW/m²) of radiant heat, and it determines the construction requirements for the roof, walls, windows, doors, decks and subfloor.
There are six levels:
- BAL-LOW: The risk is considered too low to warrant specific construction requirements under AS 3959.
- BAL-12.5: Radiant heat up to 12.5 kW/m². The main concern is ember attack.
- BAL-19: Radiant heat above 12.5 and up to 19 kW/m². Ember attack is the main threat, with increasing heat exposure.
- BAL-29: Radiant heat above 19 and up to 29 kW/m². Ember attack is accompanied by higher heat exposure.
- BAL-40: Radiant heat above 29 and up to 40 kW/m². Ember attack, high radiant heat and a likelihood of flame contact.
- BAL-FZ (Flame Zone): Radiant heat above 40 kW/m². Direct exposure to flames, heat and embers.
Embers are the leading cause of home loss in bushfires. They can travel well ahead of the fire front, lodge in gaps and gutters, and ignite a home long after the front has passed. This is why so many roofing requirements focus on sealing gaps, using non-combustible materials and keeping embers out of the roof space.
How Your BAL Is Determined
You cannot simply choose a BAL. It is assessed from the characteristics of your site and the surrounding area. Under the AS 3959 simplified procedure (Method 1), the assessment considers:
- Fire Danger Index (FDI): Queensland is assigned an FDI of 40 in AS 3959, which is used as the baseline for assessments.
- Vegetation classification: Vegetation is grouped into types such as forest, woodland, scrub, shrubland, rainforest and grassland. Forest and woodland generally present a higher risk than managed grassland or low-threat vegetation.
- Distance to the vegetation: The closer your building is to the hazard, the higher the BAL.
- Effective slope: Land that slopes downhill from your building toward the vegetation increases fire intensity and the resulting BAL, because fire travels faster uphill.
In South-East Queensland, bushfire-prone areas are identified through State and local government mapping. Many properties on the fringes of Brisbane, such as in the western suburbs and the D'Aguilar foothills, as well as hinterland communities like Tamborine Mountain, Maleny, Samford Valley and Beechmont, include mapped vegetation and buffer areas. A mapped area only tells you the site is bushfire prone. It does not give you a BAL. For that, you need a site-specific assessment, usually carried out by a qualified bushfire consultant, an accredited practitioner or your building certifier. The assessment is typically required as part of your building application.
Why the BAL Matters for Your Roof
Roofs are especially vulnerable because they present a large, horizontal surface that catches embers. They also have many junctions, such as ridges, valleys, eaves, vents and penetrations, where embers can find a way in. The higher the BAL, the more stringent the requirements become for:
- the roof covering itself (tiles or sheeting)
- sarking, insulation and anti-condensation blankets under the roof
- gaps at roof-to-wall junctions, eaves and fascias
- roof penetrations, such as flues, vents and pipes
- skylights and roof lights
- gutters, valley gutters and leaf guards
- roof-mounted equipment, such as evaporative coolers and solar hot water systems
Roofing Materials by BAL Rating
BAL-LOW
AS 3959 imposes no additional construction requirements. You can choose roofing materials on the basis of cost, appearance, thermal performance and the regional wind and cyclone considerations that normally apply under the NCC. Even so, many SEQ homeowners near bushland voluntarily use non-combustible materials because they are suited to Queensland's climate anyway.
BAL-12.5, BAL-19 and BAL-29
These three levels share a similar set of roof requirements, which increase in the extent to which other building elements must also be protected. In general:
- Non-combustible roof coverings are required. Concrete tiles, terracotta tiles and metal sheeting such as Colorbond steel and Zincalume are the most common compliant choices.
- Gaps must be sealed. Where tiles or profiled sheets meet the fascia, valley or ridge, gaps need to be sealed or covered so embers cannot enter. Tile ends are typically sealed with an appropriate sealant, mortar or proprietary ember-resistant products, and corrugated or ribbed sheeting uses profiled sealing strips or similar.
- Roof ventilators and penetrations need to be fitted with ember guards. These are typically corrosion-resistant steel or bronze mesh with a maximum aperture of 2 mm.
- Sarking beneath the roof covering must be non-combustible or have a low flammability index (not more than 5 when tested to AS 1530.2). Standard reflective foil laminates and sarking products are available in compliant versions, but not all products are, so verify the product data.
- Gutters and leaf guards should be non-combustible, with any mesh fitted to meet the 2 mm aperture limit.
- Valleys need to be non-combustible, and any exposed gaps at junctions should be sealed or screened.
It is important to note that the finer details of these requirements vary across BAL-12.5, BAL-19 and BAL-29, particularly for skylights, roof-mounted equipment and ancillary items. Always confirm the specifics against AS 3959 and your approved building plans.
BAL-40
At BAL-40, the standard requirements tighten further, with additional attention to radiant heat and the possibility of flame contact. Roof coverings must remain non-combustible, and all gaps, penetrations and junctions need to be fully ember-proofed. Skylights and roof lights face stricter conditions, which commonly involve non-combustible frames and appropriate glazing, and polycarbonate and similar plastic domes are generally not suitable unless they meet the standard's tested requirements. Roof-mounted equipment such as evaporative coolers must also meet the relevant provisions, which commonly include non-combustible construction and ember screening.
BAL-FZ (Flame Zone)
BAL-FZ is the most demanding category. Compliance typically requires construction that has been tested against flame exposure, and the NCC and AS 3959 require the roof and other building elements to meet strict criteria, often involving more specialised design and testing. In many cases, a building in the Flame Zone will also need a performance-based solution designed with a bushfire specialist, and approval may take longer. Because the requirements are more complex, it is important to engage a certifier and an experienced roofing contractor early in the design process.
Common Roofing Materials Compared
Metal sheeting (Colorbond, Zincalume and similar)
Steel roofing is non-combustible, lightweight and widely used across South-East Queensland. It performs well in BAL-12.5 through BAL-29 when installed with ember-sealing at the ridge, barge and eaves. It is a popular choice because it also suits the region's heavy rain, UV exposure and severe storm conditions. Pay close attention to insulation and sarking products beneath the sheets, because those must also comply.
Concrete tiles
Concrete tiles are non-combustible and offer good thermal mass. The key bushfire vulnerability is the gaps between tiles and at the ridge and hips. Compliant installation requires sealing or covering those gaps, particularly at the eaves and in valleys, to prevent ember entry.

Terracotta tiles
Terracotta tiles are also non-combustible and offer similar bushfire characteristics to concrete tiles. As with concrete tiles, the focus is on sealing the gaps at junctions.
Timber shingles and shakes
Timber roofing is combustible and is generally unsuitable in bushfire-prone areas that require non-combustible roof coverings. If you are renovating a heritage-style home that has timber shingles, speak to your certifier before making any decisions.
Plastic and polycarbonate sheeting
These are combustible materials and typically cannot be used as a main roof covering in BAL-rated areas. They may be allowed in limited applications, such as certain roof lights, if they meet the relevant standard, so check before specifying them for patios or verandah extensions.
Does BAL Apply When You Replace an Existing Roof?
BAL requirements apply most clearly to new buildings and to new work on existing buildings in a designated bushfire-prone area. Whether a full roof replacement or re-sheeting needs to meet current BAL requirements depends on the scope of work, local government rules and the building approval pathway. It is common for re-roofing to trigger a requirement to use compliant materials and details, particularly where the work includes replacing sarking, penetrations or the entire roof structure. Because this can vary, confirm the requirements with your building certifier or local council before starting any roof replacement.
Steps to Take Before Starting a Roofing Project
- Check whether your property is in a bushfire-prone area using your local council or State planning maps.
- Obtain a BAL assessment from a qualified assessor or through your certifier.
- Review your approved plans and the BAL report to see how they apply to the roof, gutters, vents and skylights.
- Choose compliant products and ask suppliers for documentation, such as flammability test data for sarking and insulation.
- Engage an experienced roofing contractor who understands ember-proofing details and can install the roof according to the standard.
- Keep records of compliance, product specifications and certification for insurance and future sale.
Beyond Compliance: Practical Roof Protection Tips
Meeting the BAL requirements is a minimum standard. It does not guarantee that a building will survive a bushfire. To improve your roof's resilience, consider the following:
- Keep gutters and valleys clear of leaves and debris, especially before the spring and early summer fire season in South-East Queensland.
- Trim overhanging branches and keep trees and large shrubs away from the roofline.
- Inspect ember screens, sealants and flashings regularly, because they can deteriorate over time.
- Check roof penetrations after any trade work, such as antenna, solar or air-conditioning installation, to confirm that gaps have been re-sealed.
- Store firewood, gas bottles and other combustibles away from the house and the roof overhang.
Insurance and Resale Considerations
Insurers in bushfire-prone parts of South-East Queensland may ask about your BAL rating and the materials used in your home. Keep your BAL report and compliance documents together with your policy paperwork. A compliant, well-documented roof can also be https://roofrestorationseq.com.au/ a selling point, because buyers and their advisers are increasingly aware of bushfire risk in places such as the hinterland, the D'Aguilar Range foothills and the Scenic Rim.
Key Takeaways
Your BAL rating is determined by vegetation, distance, slope and the regional fire danger index, and it directly governs the roofing materials and details you can use. In lower BAL categories, non-combustible coverings, ember-proofed gaps, mesh-protected vents and compliant sarking form the foundation of a bushfire-ready roof. At higher categories, the requirements for skylights, equipment and the roof system as a whole become more demanding. Because the specifics are technical and vary with each site, the best approach is to confirm your BAL early, discuss it with your certifier, and work with a roofing contractor who is familiar with AS 3959 and the conditions across South-East Queensland.